|
Build Your Online Product Catalogs?
Product Name: |
Residual chlorine on-line equipment
|
Supply Ability: |
|
Related proudcts |
industrial controlle, |
Specifications |
XHCL-7135 |
Price Term: |
|
Port of loading: |
|
Minimum Order |
|
Unit Price: |
|
|
XHCL-7135 intelligent residual chlorine control equipment is a on-line ***ecting instrument for residual chlorine, chlorine dioxide and ozone the ***ection. It adopts advanced constant voltage transducer, high sensitivity, rapid signal response, accurate measurement, stable performance and easy maintenance. It is used by many sewerage treatment units, such as steel plant and chemical co***nies. In the condition of less than 0.1ppm residual chlorine, it has showed good performance. It can connect with SZ283 chlorine sensor provided by Italy B&C co***ny and it can replace CL7685,CL3630,CL7635 ***ecting equipments. For the manufacturer of chlorine dioxide equipment, it is high quality supporting instrument to improve the competition and save cost. Feature: Measure and display the content of residual chlorine, adjustable rangeļ¼?-2ppm,0-20ppm). According to the chlorine value, the analog output is 4-20mA and the output range of the current is settable. 2-channel relay output: upper limit output and lower limit output RS485 communication, standard MODBUS-RTU communication protocol Chlorine automatically control(current output control, pulse output control)
Residual chlorine sensor XHCL-283 constant voltage electrode applies to test the residual chlorine, chlorine dioxide, and ozone in water. The constant voltage testing method can keep a stable electric potential at the testing terminal of the electrode. Different objects to be tested at the potential will generate different current intensity. It is a low-voltage measuring system consisted of two platinum electrodes. Flowing through the testing electrode, the residual chlorine, dioxide chlorine and ozone will be consumed, so when the water sample is measured, the water must continuously flow through the electrode. Duo to the influences of the resistance the water sample has and the oxidation-reduction electric potential, the traditional current measuring method can not keep the linear relationship between the concentration of the ingredient and the curr |
Company: |
Changzhou Xionghua Tongtai Automation Equipment Co.,Ltd
|
Contact: |
Ms. jie Chen |
Address: |
Room13-315 QianShengLanTing ,NO. 15,LanLing Road,TianNing Distrit |
Postcode: |
213001 |
Tel: |
8615306116671 |
Fax: |
86-519-86968907-832 |
E-mail: |
|
|
|
|